← DSR-SETUP-0002

RL-2026-000009 — Vibration Measurement

Measured 24 August 2026 at 20:48 · Europe/London

Measurement context

ConditionRecorded state
SupportFurniture
IsolationBuilt-in turntable suspension
FloorSuspended timber floor
Phone positionPlatter
Phone orientationFace up
Motor / platterOff / stationary
Record / stylusNot present / not tracking
SpeakersActive

Results

MetricResult
Capture RMS1.266 mg
Capture peak5.956 mg
Analysis range1–40 Hz
1–8 Hz38.67% energy · 0.787 mg RMS
8–20 Hz25.84% energy · 0.644 mg RMS
20–40 Hz35.49% energy · 0.754 mg RMS

Dominant local peaks

6.62 Hz · 0.229 mg; 5.35 Hz · 0.172 mg; 7.78 Hz · 0.140 mg; 17.42 Hz · 0.135 mg; 12.07 Hz · 0.134 mg.

Resonance context

Calculated cartridge/tonearm resonance: 7.87 Hz. A local spectral maximum occurs at 7.78 Hz near the predicted resonance region, but measurement confidence was insufficient to classify it as a significant/confident nearby feature.

Scientific limitation: the phone measures mechanical vibration at its placement point. This contextual comparison does not directly measure or prove stylus/cantilever or cartridge/tonearm resonance, acoustic feedback, motor/bearing resonance, structural resonance, a specific cause or causation.

Provenance

Resonance Lab 1.0 · iPhone16,1 · iOS 26.6.1 · analysis method vibration-1-40-1.1.0.

Measurement UUID: 4ea2086c-7c84-452a-9eef-bc02e7715107 · Author: Anonymous contributor · Publisher: Direct Sound Records.

Open the canonical structured record on GitHub.