Close-up of the Ortofon 2M Bronze cartridge and SME III tonearm on the Thorens TD 160 Super, cosmetically retouched.

Groove Scope measurement · GS-2026-0017

Ortofon 2M Bronze

Thorens TD 160 Super / SME III

A 1 kHz reference check of the Ortofon on a vintage Thorens after azimuth and anti-skate adjustment.

Measured

Measurement at a glance

The 1 kHz reference check

Michelangelo Canonico measured this system for Direct Sound Records. These figures come from the final 1 kHz capture.

Playback RPM
33.30
Under stylus load
Speed error
−0.11%
vs 33⅓ RPM
DIN-shaped W&F
0.028%
RMS
Channel balance
+0.44 dB
L−R
Avg separation
32.2 dB
1 kHz electrical crosstalk

Rotation fingerprints

Four dimensions, two channels

Each view pairs Groove Scope’s angular heatmap with its robust median profile. Choose L or R on each card. Channel assignments follow the supplied filenames.

Speed deviation

Left-channel speed-deviation rotation fingerprint and robust median profile.

Left channel selected

Harmonic distortion

Left-channel harmonic-distortion rotation fingerprint and robust median profile.

Left channel selected

Opposite-channel leakage

Left-channel opposite-channel leakage rotation fingerprint and robust median profile.

Left channel selected

1 kHz level modulation

Left-channel 1 kHz level-modulation rotation fingerprint and robust median profile.

Left channel selected

Each plot shows eight revolutions on its own relative angular reference. On smaller screens, swipe to browse all four plots.

Azimuth and anti-skate

Adjusting the SME III setup

The measurer noted an initial 5.86 dB imbalance when setting azimuth and reported a marked qualitative improvement after adjusting anti-skate. The table records the final 1 kHz capture.

Rotational behaviour

A speed pattern that repeats each turn

Over eight revolutions, both speed fingerprints show a faster region near the beginning and end of each plotted turn and a slower region in the middle. The recurrence shows where the speed varied within the rotation.

Measurement chain

The playback system

Turntable
Thorens TD 160 Super
Tonearm
SME III
Cartridge
Ortofon 2M Bronze
Preamplifier
ART preamp

Open technical record

Behind the playback chain

The technical record includes the original report, structured results, file checksums and the measurement method.

Measurement results

The complete capture, in numbers

The table preserves the report’s figures for playback speed, weighted and unweighted stability, channel behaviour and harmonic distortion.

MetricMeasured result
Playback speed under stylus load33.30 RPM
Playback speed error−0.11% vs 33⅓ RPM
Settled speed range33.22–33.37 RPM
Settled speed span0.15 RPM
DIN-shaped wow & flutter RMS0.028%
Raw speed variation, unweighted RMS±0.138%
Raw speed variation, unweighted 2-sigma±0.276%
Raw wow, unweighted RMS0.134%
Raw flutter, unweighted RMS0.032%
Channel balance, L−R+0.44 dB
Average channel separation at 1 kHz32.2 dB
Electrical crosstalk, L→R−33.0 dB
Electrical crosstalk, R→L−31.3 dB
Directional crosstalk difference1.72 dB
Total harmonic distortionLeft 1.23%, right 1.26%
THD difference, L−R−0.03 percentage points
Second harmonic (H2)Left −38.6 dB, right −38.5 dB
Third harmonic (H3)Left −49.7 dB, right −50.1 dB
Fourth harmonic (H4)Left −57.4 dB, right −58.8 dB
Fifth harmonic (H5)Left −68.3 dB, right −66.4 dB
H2 difference summaryRight 0.1 dB higher
H3 difference summaryLeft 0.5 dB higher

Report note. Total harmonic distortion in the left channel changed most during the capture. The report calls for repeating the measurement before making further cartridge setup changes.

The table preserves the precision of the reported channel readings and their differences.